| Main technical parameters |
Input signal | Analog quantity thermocouple: standard thermocouple --- K, E Resistance: standard thermo-resistance ---- Pt100 Current: 0∼10 mA, 4 mA∼20 mA etc. (input resistance≤250Ω) Voltage: 0∼5 V, 1 V∼5 V, mV etc. (input impedance≥250 KΩ) Switch quantity start, stop, clean Input signal switch temperature compensation: Pt 100, K, E, 0∼10 mA, 4∼20 mA, 0∼5 V, 1∼5V (can free switch) Pressure compensation: 0∼10 mA, 4∼20 mA, 0∼5 V, 1∼5 V (can free switch) Flow input: 0∼10 mA, 4∼20 mA, 0∼5 V, 1∼5 V (can free switch) |
| Output signal | Analog quantity DC 4∼20 mA (load resistance≤500Ω) DC 0∼10 mA (load resistance≤750Ω) DC 1∼5 V (load resistance≥250KΩ) DC 0∼5 V (load resistance≥250KΩ) Switch quantity Relay control output ---- ON/OFF with return difference Contact capacity: AC 220V/3A; DC 24V/5A (resistive load) Communication mode RS 232C, RS485 Baud rate 300∼9600 bps (free set) Feed output DC 24 V, load ≤30 mA |
| Characteristic | Measuring accuracy ±0.2%FS or ±0.5%FS Resolution ±1 character Display mode Full Chinese big screen (with backlight) LCD liquid crystal display Display current date and time Display 6-digits (0∼999999) instantaneous flow value Display 11- digits (0∼99999999999) accumulate flow value Display 6- digits (-199999∼999999) temperature compensation value Display 6- digits (-199999∼999999) pressure compensation value Display 4- digits (-1999∼9999) flow (differential pressure, frequency) value Display 10- digits (0∼9999999999) super-compression factor Control mode can select high/lower limit or high-higher/low-lower limit control, with normal open/close output Control setting value free set for control setting value and return difference value in the full range Fixed-quantity control can select flow fixed-quantity to control, LED output indicating Can select flow quantitative process control, LED output indicating Compensation mode temperature pressure automatic compensation Parameter setup panel touch lightly keystroke digital set Setting value of parameter is permanent retention after power failure Cipher lock for setting value of parameter Protection mode Flow accumulation remains more than 5 year after power off Under-voltage of power source can be automatic reset Abnormal work can be automatic reset |
|
|
Intelligent programmable natural gas flow integrated controller
Send a message directly to this member
« Prev Product
...
8
9
10
11
12
13
14
...
Next Product »
You can use the keys "←", "→" on your keyboard to turn pages